Broadcast News

Bookmark and Share
28/01/2013

NUGEN Audio At BVE 2013

At BVE 2013, NUGEN Audio will showcase its complete line of industry-leading solutions for loudness correction that offer a smarter approach to meeting new loudness regulations and raising the quality of broadcast audio.
NEW — LM-Correct: Stand-Alone Loudness Tool
For the first time, LM-Correct is available as a file-based program, taking its speed and simplicity outside the Avid® environment. LM-Correct is designed to offer automatic, faster-than-real-time loudness analysis and correction.
LM-Correct is ideal for rapid, intuitive correction in situations where time is limited, providing an automatic method of rapidly conforming audio to current loudness standards. LM-Correct can be used as a one-stop solution for loudness correction, fixing audio that has not been mixed with loudness standards in mind, or in conjunction with a real-time loudness meter such as VisLM to "fine tune"audio mixed to loudness requirements from the outset. LM-Correct can also be used as a final "back-stop" processor, ensuring that finished files are within specification and performing a fix where errors are found.
NEW — VisLM v1.6: Visual Loudness Metering Plug-In Now Available in Avid® AAX Format and 64-Bit OS X®
NUGEN Audio is offering VisLM 1.6, a significant update to its visual loudness monitoring tool. With this version, VisLM is now available for the first time in the Avid® AAX format. Additionally, VisLM is now available in a 64-bit OS X® version.
VisLM 1.6 also includes a new dialog gate option that allows automatic measurement of dialog sections within the source material. Measurements can now be written to automation tracks so that elements such as the loudness profile and true-peak clips can be seen against the waveform in the digital audio workstation timeline for diagnostic referencing.
With detailed, objective loudness measurement, history and logging facilities, VisLM provides an easy-to-use ITU, ATSC and EBU standard-compliant way to measure, compare, and contrast loudness during production, broadcast, and post production, on the fly or for entire sections of audio. Offering true-peak level metering (inter-sample accurate level monitoring), loudness range (to help decide if and how much dynamic compression to apply), momentary "instantaneous loudness" for mixing by ear, short term loudness (three second time window) and program loudness (long-term integrated loudness measurement), VisLM is a comprehensive tool that helps audio professionals cut through the complexity of loudness compliance.
VisLM is available in two versions, VisLM-C (compact) and VisLM-H (history). Both versions are available in 2.0 and 5.1 formats.
ISL: Inter-Sample True-Peak Limiter
The NUGEN Audio ISL inter-sample True-Peak limiter is designed for the control of peak levels in audio signals from mono through to 5.1. Unlike traditional approaches to limiting, ISL offers a true brick-wall solution, measuring inter-sample peaks and allowing the user to define the true-peak limit of the audio output (rather than the more traditional threshold control at which limiting begins to take effect).
Easy to use and totally transparent, ISL is based on the standardized true-peak algorithms of ITU-R B.S. 1770 and related standards, and is suitable for the control of audio for post-production and broadcast applications. True-peak limiting can also be used to ensure that downstream codecs (mp3, AAC etc.) do not introduce distortion into the signal. While ISL has been designed for limiting relatively dynamic high-quality audio, it can also be used to hard limit and reduce dynamic range considerably if this is required.
LMB: Batch Processing Loudness Correction Tool for High Throughput Applications
The NUGEN Audio LMB system is an off-line file-based loudness analysis and correction program designed for rapid assessment and correction of files for loudness and true peak content to ITU-R BS. 1770- and EBU R128-based specifications.
With a drag-and-drop interface and/or specific watched folders, LMB saves operator time by automatically handling the process of checking and conforming files to multiple broadcast criteria. LMB produces detailed post-mortem logs and includes a built-in graphing facility. LMB can be fully integrated into an automated system using the optional command-line interface and XML file output logs.
www.nugenaudio.com


VMI.TV Ltd

Top Related Stories
Click here for the latest broadcast news stories.

30/09/2015
NUGEN Audio Releases New DSP VisLM-H2 Loudness Meter
NUGEN Audio has introduced a new DSP option for its VisLM-H2 visual loudness meter, targeted to users of Avid Pro Tools HDX systems. Leveraging advanc
24/01/2013
NUGEN Audio At BVE 2013
At BVE 2013, NUGEN Audio will showcase its complete line of industry-leading solutions for loudness correction that offer a smarter approach to meetin
19/07/2012
Jünger Audio Makes Audio Loudness Its Focus At BIRTV 2012
Dynamics specialist Jünger Audio will focus on controlling audio loudness in the broadcast chain at this year’s BIRTV convention in China (August 22nd
14/05/2012
Jünger Audio Makes Audio Loudness Its Focus At Broadcast Asia 2012
Dynamics specialist Jünger Audio will focus on controlling audio loudness in the broadcast chain at this year’s Broadcast Asia convention in Singapore
10/04/2015
NUGEN Audio Releases Loudness Toolkit 2
NUGEN Audio has released Loudness Toolkit 2, the latest generation of the company's suite of loudness metering and correction tools. Consisting of the
15/03/2016
University Selects NUGEN Audio VisLM
The University of Birmingham's student-operated television station, Guild TV, has selected NUGEN Audio's VisLM loudness metering plug-in. Guild TV is
15/02/2013
New Loudness Partnership Improves Compliance For Quantel Users
Quantel has announced support for NUGEN Audio's VisLM loudness metering software. NUGEN Audio's VisLM is available on Quantel's broadcast editors in t
05/02/2014
NUGEN Audio Prepares For BVE 2014
NUGEN Audio is to showcase a range of its products, including the new MultiMonitor software for loudness and true-peak monitoring, at this year's BVE
26/03/2014
NUGEN Audio To Unveil Complete Family Of Solutions At NAB 2014
With a special emphasis on the emerging loudness requirements of American broadcasters, NUGEN Audio is presenting its complete family of industry-lead
04/10/2013
ZEN And The Art Of Loudness Metering
Television loudness has been a viewer’s concern for decades, but recent ITU standardisation has focussed the attention of programme creators on achiev
15/01/2013
NUGEN Launches VisLM Version 1.6
NUGEN Audio has released VisLM version 1.6, a significant update to the company's visual loudness monitoring tool. For the first time, VisLM is now av
03/09/2018
Signum Audio To Unveil New Bute Loudness Normaliser At IBC
Scotland-based developer Signum Audio is to unveil its new Bute Loudness Normaliser at the upcoming IBC 2018 (Stand 9.LP30). Bute Loudness Normaliser
02/05/2018
Signum Audio Releases New Integrated Loudness Solution
Signum Audio has released its brand new integrated loudness solution, the Bute Loudness Suite. The suite comprises of an Analyser, True Peak Brickwall
05/04/2018
Signum Audio Releases Bute Loudness Analyser
Signum Audio has released Bute Loudness Analyser, its first ever product. The new audio company, based in Edinburgh, Scotland, is introducing pro-audi
12/05/2017
Jünger Audio Delivers Loudness Control To Al Jazeera
One of the world's largest news organisations, Al Jazeera, has chosen Jünger Audio's acclaimed loudness management technology to control and regulate